Specifications
measuring media | gas liquid compatible with 316LSS | ||
pressure range | Bar | Gauge:-1...0~0.1...1000Bar | |
Bar | Absolute:35kpa...25Bar | ||
overload pressure | %FS | 200 | |
burst pressure | %FS | 250 | |
power supply | Vdc | 12-32 | |
output signal | 4-20mA,0.5-4.5VDC,0-5VDC,RS485 | ||
zero offset | %FSO | 1 maximum | |
accuracy | %FSO | ±0.25 | |
long-term stability | %FSO/year | 0.15 | |
Load resistance | Ω | 250~1150Ω (for 4~20 mA current loop) | |
storage temperature range | oC | -40~+120 | |
operating temperature range | oC | -30~+80 | |
compensated temperature range | oC | -30~+80 | |
temperature coefficient of ZERO | %FSO/ | ±0.02 | |
temperature coefficient of SPAN | %FSO/ | ±0.04 | |
process connection | thread | G1/2”,M20X1.5 or others | |
electrical connection | DIN 43650 Hirschmann connector | ||
environment protection | IP rating | IP 65 | |
pressure membrane material | Silicon | ||
material of wetted parts | 316L SS | ||
housing material | 304 SS |